red02_next.gifHome

red02_next_1.gifAbout Us

 red02_next_2.gif Privacy

red02_next_3.gifTerms

red02_next_4.gifContact

red02_next_5.gifLinks  

red02_next_6.gifUPS

 

Industrial Humidity / Temperature Transmitters

Click for Support Form

 

Industrial Humidity / Temperature Transmitters

 

High-End Industrial Humidity / Temperature Transmitter
 High Humidity and Chemical Applications ...... Series EE33


EE32 / EE33 High End Industrial Humidity / Temperature Transmitter
 

Data Sheet Series EE33
Manual Series EE33
Monolithic Humidity / Temperature Sensor
Manual Data Logging Software EE33
Calculated Accuracies EE33
Ethernet Protocol EE33
   
 
  • Working range: 0 - 100 %RH
  • Temperature range: -40 to +180 °C (-40 to 356 °F)
  • Housing: Metal or Polycarbonate
  • Unique monolithic measuring cell
  • Measurement near condensation (separate T-probe)
  • Purge of chemical contamination
  • Full temperature compensation
  • Pressure tight version up 100 bar (1450 psi)
  • Alarm output and local display optional
  • Interchangeable and remote sensor probe up to 20 m (65 feet)
  • Two analogue outputs free selectable and scalable
  • RS 232 interface for configuration
  • Dew point, absolute humidity and other calculated values
  • Data output via RS232 serial interface
  • RS485 and Ethernet network capability
  • Calibrated against NIST traceable factory standards
 
   

 

 

Multifunctional Industrial Humidity / Temperature Transmitter
Humidity / Dewpoint / Wet Bulb / Mixing Ratio ...... Series EE31


EE29 / EE31 Multifunctional Industrial Humidity / Temperature Transmitter

   
 
  • Working range: 0 - 100 %RH
  • Temperature range: -40 to +180 °C (-40 to 356 °F)
  • Housing: Metal or Polycarbonate
  • Full temperature compensation
  • Pressure tight version up 20 bar (300 psi)
  • Alarm output and local display optional
  • Interchangeable and remote sensor probe up to 20 m (65 feet)
  • Two analogue outputs free selectable and scalable
  • RS 232 interface for configuration
  • Dew point, absolute humidity and other calculated values
  • Data output via RS232 serial interface
  • RS485 and Ethernet network capability (optional)
  • Calibrated against NIST traceable factory standards
 
   

 

 

Economical Industrial Humidity / Temperature Transmitter
Dew and Frost Point Temperature ...... Series EE23


EE23 Economical Industrial Humidity / Temperature Transmitter
 

Data Sheet Series EE23
Manual Series EE23
   
 
  • Working range: 0 - 100 %RH
  • Temperature range: -40 to +120 °C (-40 to 248 °F)
  • Housing: Metal or Polycarbonate
  • Dewpoint and frost point temperature calculation
  • On site calibration
  • Wall and duct mount version
  • Remote sensor probe up to 20 m (65 feet)
  • Alarm output and local display optional
  • Version with 5 mm (0.2 inch) remote probe
  • Calibrated against NIST traceable factory standards
 
   

 

 

Digital Industrial Humidity / Temperature Transmitter
Interchangeable Probes ...... Series EE
22


EE22 Humidity / Temperature Transmitter w/ Interchangeable Digital Probe
 

Data Sheet Series EE22
Manual Series EE22
   
 
  • Working range: 0 - 100 %RH
  • Temperature range: -40 to +80 °C (-40 to 176 °F)
  • Housing: Metal or Polycarbonate
  • Interchangeable probes without recalibration
  • Calibration data stored in sensor probes
  • 1 RH / T probe or 2 separate probes for RH and T
  • On site calibration
  • Remote sensor probe up to 10 m (32 feet)
  • Alarm output and local display optional
  • Clean room wall mount version with rear cable entry
  • Calibrated against NIST traceable factory standards
 
   

 

 

Industrial Humidity / Temperature Transmitter
Intrinsically Safe Applications ...... Series EE
30-EX


EE30-EX Intrinsically Safe Humidity / Temperature Transmitter
 

Data Sheet Series EE30-EX
Manual Series EE30-EX

   
 
  • Working range: 0 - 100 %RH
  • Temperature range: -40 to +180 °C (-40 to 356 °F)
  • Intrinsically Safe version II (1) G [EEx ia] IIC / II 1/2 G EEx ia IIC T6
  • Full temperature compensation
  • Two analogue outputs free selectable and scalable
  • Pressure tight version up 15 bar (215 psi)
  • Remote sensor probe up to 10 m (32 feet)
  • RS 232 interface for configuration
  • Dew point, absolute humidity and other calculated values
  • Data output via RS232 serial interface
  • Optional local display
  • Calibrated against NIST traceable factory standards
 
   
     
  Data Sheet Accessories & Filter Caps  
  Manual Radiationshield  
  IP / NEMA - A Comparison  
  Measuring Humidity - Basic  
  Humidity Calibration - Basic  
  Humidity Sensor Elements  
  RS232 Industrial Transmitter Protocol  
  EE3X Configuration Software - ZIP (29 MB)  
 

Please note: Manual data files may be quite large, please be patient while downloading
The manuals are for information purposes only and should not be used to install or operate the instrument
 

Phone: +1-215-340-2650
Fax:    
+1-215-340-3670
 

Home  ·   About us  ·   Privacy  ·   Terms  ·   Contact  ·   Links  ·   UPS  ·   Engineering information  ·   News and updates  ·   Industrial humidity transmitters  ·   HVAC humidity transmitters  ·   Humidity sensors and OEM configurations  ·   Additional humidity instrumentation  ·   Inline dewpoint meters  ·   Dewpoint transmitters  ·   Portable dewpoint meters  ·   Carbon dioxide transmitters  ·   Air velocity instrumentation  ·   Handheld instrumentation  ·   Low and extreme low flowmeters  ·   High viscosity oval gear flowmeters  ·   Gas and liquid turbine flowmeters  ·   Ultrasonic flowmeters  ·   Beverage flowmeters for wine, beer and spirits  ·   Inline Atrato  ·   Handheld meters for RH, T and AV  ·   Air Velocity / Temperature Transmitters

The contents of this site are ©2010 JLC International.  All rights reserved.  Powered by Sitecats Web Development